<LOGO>
FM Transmitter Measurement Report
Created: 2025-02-25 13-59-40
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
88.20 MHz 5/5, 54 dBuV GENE88.2
Pilot RDS Phase Difference
7.2 kHz 4.0 kHz 1 deg
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 0,0 kHz
MIN Hold Max. Samples at Total Samples % above 75,0 kHz
16 kHz 72 kHz 10084 0,1091
Modulation Power
Limit Measuring Tolerance
10,0 dBr 0,0 dBr
MIN AVE MAX % above 10,0 dBr
8,3 dBr 8,50 dBr 8,7 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"GENE88.2" FE50 0 (No PTY) 1 0 1 2 --:--
RT
"GENERATIONS - SKUNK - MWEN EN SA (FT. LETO & TIITOF) "
AF EON
88.2, 101.3 MHz -
FM Scope Station: 88.20 MHz, signal: 5/5 (53 dBuV) Max at: 72 kHz MIN: 16 kHz % above 75 kHz: 0,1091 Acquired: 2025/02/25 13:58:36 Total samples: 10084 Equivalent time: 0:08:24 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 1000 2000